Related Experiment Video
Updated: Apr 28, 2026

The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
A novel technique to improve the diagnostic yield of negative sestamibi scans
Sapna Nagar1, David D Walker2, Omran Embia1
1Endocrine Surgery Research Program, Department of Surgery, Pritzker School of Medicine, University of Chicago, Chicago, IL.
Introduction:
Minimally invasive parathyroidectomy is successful in achieving cure for most patients with primary hyperparathyroidism. Most surgeons rely on preoperative imaging as part of the workup for localization. Ultrasonography and sestamibi are the 2 most commonly used preoperative imaging studies. When these 2 studies are positive and concordant the preoperative localization is straightforward. However, when ≥1 of these studies is negative, the preoperative localization is suspect. We hypothesize that the yield of useful localizing information from "negative" sestamibi scans can be increased in certain situations. Specifically, in cases where the thyroid lobe length seen on sestamibi is discordant from the lobe length of the ultrasonography, this often represents a "hidden" parathyroid adenoma. If our hypothesis is correct, this could lead to decreased resource utilization in cases of nonlocalized parathyroid adenomas.
Methods:
We retrospectively analyzed our database of patients with primary hyperparathyroidism who underwent parathyroidectomy from 2005 to 2011. The anteroposterior views of early phase sestamibi were analyzed for thyroid lobe lengths. A ratio of the length of the right lobe to left lobe was calculated. The thyroid lobe lengths on ultrasonography were measured and similar ratios were calculated. The difference in ratios between sestamibi and ultrasonography was calculated for each patient. A difference in ratios from sestamibi and ultrasonography that corresponded with a "hidden" parathyroid on the side of the additional length on sestamibi at the time of surgery was considered a positive finding. When the difference in ratios from the 2 images did not correspond with a "hidden" parathyroid at the time of operation, it was considered a negative finding.
Results:
There were 59 patients with single-gland disease, negative sestamibi, and images available for review. There were 32 patients (54%) with the positive finding of a "hidden" parathyroid corresponding with a difference in thyroid lobe length ratios from sestamibi and ultrasonography. The overall mean difference in ratios between sestamibi and ultrasonography was 0.37 ± 0.32. The mean ratio difference in the group of patients with a negative "hidden" parathyroid was 0.11 ± 0.02, and the mean ratio difference in the group of patients with a positive "hidden" parathyroid was 0.58 ± 0.05 (P < .001). When a difference in ratios of ≥0.23 was obtained, this predicted a "hidden" parathyroid with a sensitivity of 93.8% and specificity of 85.2%. There were 39 patients with multigland disease, negative sestamibi, and images available for review. None of these patients had a ratio difference of ≥0.23. The mean ratio difference for patients with multigland disease was significantly lower than that of the single-gland disease (0.08 ± 0.06 vs 0.37 ± 0.32; P < .001).
Conclusion:
Discordance between thyroid lobe lengths on the early phase sestamibi compared with ultrasonography has led to successful preoperative identification of parathyroid adenomas, even though the sestamibi was traditionally read as negative. This finding has not been previously described, seems to be reliable, and can lead to improved preoperative localization and decreased resource utilization in this subset patients.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Magnetic Resonance Imaging