Related Experiment Video
Updated: Apr 28, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Systemic-pulmonary artery shunts in infants: modified Blalock-Taussig and central shunt procedures
1Chris Barnard Division of Cardiothoracic Surgery at Red Cross Children's Hospital, Cape Heart Centre, University of Cape Town, Cape Town, South Africa.
Access is gained through a midline sternotomy, the thymus partially excised and the superior part of the pericardium is opened. The innominate vein is retracted and the innominate artery is mobilized up to the bifurcation. The aorta is retracted to the left, the superior vena cavae to the right and the right atrial appendage inferiorly. The adventitia around the right pulmonary artery (PA) is dissected, taking care to incise the bulky pericardial reflection between the superior vena cavae and the trachea. Heparin is administrated. An occlusive clamp is applied to the right PA to test for haemodynamic tolerance prior to proceeding with the interposition of a suitable size artificial vascular prosthesis, based on the weight of the patient, between the innominate artery, or proximal subclavian artery and the right PA. Alternatively, if a sufficient main PA is present and adequate flow from a patent ductus arteriosus an end-to-side interposition shunt may be constructed between the ascending aorta and the main PA, provided the patient is stable with the test occlusion of the main PA. The management of the patent arterial ductus depends on whether or not there is forward flow through the PA.
Access is gained through a midline sternotomy, the thymus partially excised and the superior part of the pericardium is opened. The innominate vein is retracted and the innominate artery is mobilized up to the bifurcation. The aorta is retracted to the left, the superior vena cavae to the right and the right atrial appendage inferiorly. The adventitia around the right pulmonary artery (PA) is dissected, taking care to incise the bulky pericardial reflection between the superior vena cavae and the trachea. Heparin is administrated. An occlusive clamp is applied to the right PA to test for haemodynamic tolerance prior to proceeding with the interposition of a suitable size artificial vascular prosthesis, based on the weight of the patient, between the innominate artery, or proximal subclavian artery and the right PA. Alternatively, if a sufficient main PA is present and adequate flow from a patent ductus arteriosus an end-to-side interposition shunt may be constructed between the ascending aorta and the main PA, provided the patient is stable with the test occlusion of the main PA. The management of the patent arterial ductus depends on whether or not there is forward flow through the PA.

