Related Experiment Video
Updated: Apr 27, 2026

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Predictors for an unsuccessful INtubation-SURfactant-Extubation procedure: a cohort study
Nis Brix, Anna Sellmer, Morten Søndergaard Jensen
1Perinatal Epidemiology Research Unit, Aarhus University Hospital, Brendstrupgaardsvej 100, Aarhus N 8200, Denmark. tbh@dadlnet.dk.
Background:
The INtubation-SURfactant-Extubation (INSURE) is a procedure that is increasingly being used to treat the respiratory distress syndrome in preterm infants. The objective of this study was to identify predictors for an unsuccessful INSURE procedure.
Methods:
The neonates included were less than 32 weeks' gestation, treated with surfactant in the neonatal intensive care unit, and born 1998-2010. INSURE was defined as surfactant administration during intubation for less than 2 hours without the need for mechanical ventilation. INSURE success was defined as no re-intubation within 72 hours after INSURE, and INSURE failure was defined as re-intubation within 72 hours after INSURE. An unsuccessful INSURE procedure was either INSURE failure or mechanical ventilation for more than 24 hours immediately after surfactant administration. All predictors were defined a priori and were present before surfactant administration. Multivariate logistic regression was performed.
Results:
In total, 322 neonates were included: 31% (n = 100) had INSURE success, 10% (n = 33) had INSURE failure, 49% (n = 158) needed mechanical ventilation for more than 24 hours, and the remaining 10% (n = 31) needed mechanical ventilation for less than 24 hours. Predictors for INSURE failure were low gestational age and hemoglobin below 8.5 mmol/l. Predictors for mechanical ventilation for more than 24 hours were low gestational age, Apgar at 5 minutes below 7, oxygen need above 50%, CO2 pressure above 7 kPa (~53 mmHg), pH below 7.3, lactate above 2.5 mmol/l, need for inotropes, and surfactant administration shortly after birth, whereas preeclampsia reduced the risk.
Conclusions:
We identified specific predictors associated with an unsuccessful INSURE procedure. Keeping high-risk neonates with one or several predictors intubated and treated with mechanical ventilation after surfactant may prevent a re-intubation procedure.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...

