Related Experiment Video
Updated: Apr 27, 2026

Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Effect of radiologists' diagnostic work-up volume on interpretive performance
Diana S M Buist1, Melissa L Anderson, Robert A Smith
1From the Group Health Research Institute, Group Health Cooperative, 1730 Minor Ave, Suite 1600, Seattle, WA 98101 (D.S.M.B., M.L.A., D.L.M.); Cancer Control Science Department, American Cancer Society, Atlanta, Ga (R.A.S.); Departments of Family Medicine and Public Health and Preventive Medicine, Oregon Health & Science University, Portland, Ore (P.A.C.); Department of Biostatistics, University of Washington School of Public Health, Seattle, Wash (D.L.M.); Mallinckrodt Institute of Radiology, Washington University School of Medicine, St Louis, Mo (B.S.M.); Department of Radiology, University of California, San Francisco, Calif (E.A.S.); Division of Cancer Control and Population Science, Behavioral Research Program, National Cancer Institute, Rockville, Md (S.H.T.); Department of Family Medicine, University of Vermont, College of Medicine, Burlington, Vt (B.M.G.); Department of Radiology, University of North Carolina, Chapel Hill, NC (B.C.Y.); and Department of Community and Family Medicine, Dartmouth Institute for Health Policy and Clinical Practice, Geisel School of Medicine at Dartmouth, Norris Cotton Cancer Center, Lebanon, NH (T.L.O.).
Purpose:
To examine radiologists' screening performance in relation to the number of diagnostic work-ups performed after abnormal findings are discovered at screening mammography by the same radiologist or by different radiologists.
Materials And Methods:
In an institutional review board-approved HIPAA-compliant study, the authors linked 651 671 screening mammograms interpreted from 2002 to 2006 by 96 radiologists in the Breast Cancer Surveillance Consortium to cancer registries (standard of reference) to evaluate the performance of screening mammography (sensitivity, false-positive rate [ FPR false-positive rate ], and cancer detection rate [ CDR cancer detection rate ]). Logistic regression was used to assess the association between the volume of recalled screening mammograms ("own" mammograms, where the radiologist who interpreted the diagnostic image was the same radiologist who had interpreted the screening image, and "any" mammograms, where the radiologist who interpreted the diagnostic image may or may not have been the radiologist who interpreted the screening image) and screening performance and whether the association between total annual volume and performance differed according to the volume of diagnostic work-up.
Results:
Annually, 38% of radiologists performed the diagnostic work-up for 25 or fewer of their own recalled screening mammograms, 24% performed the work-up for 0-50, and 39% performed the work-up for more than 50. For the work-up of recalled screening mammograms from any radiologist, 24% of radiologists performed the work-up for 0-50 mammograms, 32% performed the work-up for 51-125, and 44% performed the work-up for more than 125. With increasing numbers of radiologist work-ups for their own recalled mammograms, the sensitivity (P = .039), FPR false-positive rate (P = .004), and CDR cancer detection rate (P < .001) of screening mammography increased, yielding a stepped increase in women recalled per cancer detected from 17.4 for 25 or fewer mammograms to 24.6 for more than 50 mammograms. Increases in work-ups for any radiologist yielded significant increases in FPR false-positive rate (P = .011) and CDR cancer detection rate (P = .001) and a nonsignificant increase in sensitivity (P = .15). Radiologists with a lower annual volume of any work-ups had consistently lower FPR false-positive rate , sensitivity, and CDR cancer detection rate at all annual interpretive volumes.
Conclusion:
These findings support the hypothesis that radiologists may improve their screening performance by performing the diagnostic work-up for their own recalled screening mammograms and directly receiving feedback afforded by means of the outcomes associated with their initial decision to recall. Arranging for radiologists to work up a minimum number of their own recalled cases could improve screening performance but would need systems to facilitate this workflow.
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Receiver Operating Characteristic Plot