Related Experiment Video
Updated: Apr 27, 2026

The Quantification of Injectability by Mechanical Testing
Published on: May 13, 2020
[A novel method for testing sterility of injections based on biothermodynamics]
Abstract:
This study aims at trying to establish a novel method of sterility test for injections based on biothermodynamics, in order to overcome the deficiencies of routine sterility tests such as long detecting cycle, low sensitivity and prone to misjudgments. A biothermodynamics method was adopted to rapidly detect the microorganism contamination of injections by monitoring the heat metabolism during the growth of microbe. The growth rate equal to or greater than zero and the heat power difference of P(i) and P(0) with three folds higher than the noise of baseline were chosen as indexes to study the heat change rule of microbe. In this way, the effectiveness of the new method to detect strains required by conventional sterility test or in injection samples was also investigated. Results showed that the Gram-positive bacteria, Gram-negative bacteria and fungi demanded by sterility testing methodology could be detected by biothermodynamics method within 10 hours, with the sensitivity lower than 100 CFU x mL(-1). Meanwhile, this method was successfully applied to the sterility test of Compound Yinchen injection (FFYC), Shuanghuanglian powder injection (SHL) and Compound Triamcinolone injection (TAND) which were sterilized with different degrees. Therefore, the biothermodynamics method, with advantages of fast detection and high sensitivity, could be a complementary solution for conventional sterility tests.
More Related Videos
09:30Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
07:28Metabolic Profiling to Determine Bactericidal or Bacteriostatic Effects of New Natural Products using Isothermal Microcalorimetry
Published on: October 29, 2020
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
In Vitro Drug Dissolution: Compendial Testing Models II
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Key Techniques in Microbiology