Related Experiment Video
Updated: Apr 27, 2026

Ratiometric Imaging of Extracellular pH in Dental Biofilms
Published on: March 9, 2016
Antiseptic effect of slightly acidic electrolyzed water on dental unit water systems
Miho Komachiya1, Akira Yamaguchi, Kaname Hirai
1Department of Removable Prosthodontics, School of Dentistry, Matsumoto Dental University.
Abstract:
Biofilm formation in dental unit water systems (DUWSs) can contaminate water from three-in-one syringes, air rotors, and low-speed handpieces. This may serve as a potential source of infection for dentists, dental staff, and patients, so these systems must be sterilized. Because slightly acidic electrolyzed water (SAEW) is often used as a disinfectant for food, the aim of this study was to investigate the possibility of using SAEW as a DUWS disinfectant. Slightly acidic electrolyzed water was injected into a dental unit and its effects evaluated. Chemical properties such as chlorine ion and potential hydrogen in the SAEW were measured. Detection of both ordinary and heterotrophic bacteria from the DUWS was performed by culture, and biofilm formation of the bacteria in the DUWS evaluated. Polymerase chain reaction (PCR) was used to detected contamination by nosocomial pathogens. Almost all the chlorine ions in the SAEW were exhausted during the two-day trials, and the pH value of the SAEW fell from 5 to 4. No viable cells were detected in the SAEW collected. Biofilm formation in the water from the DUWS with SAEW was almost at a baseline level, whereas that without SAEW was 4 times higher. The PCR analysis showed that no nosocomial infecting pathogens were detected in the SAEW. The present study demonstrated the antiseptic effect of SAEW in DUWS.
More Related Videos
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
08:20Systematic Approach to Identify Novel Antimicrobial and Antibiofilm Molecules from Plants' Extracts and Fractions to Prevent Dental Caries
Published on: March 31, 2021
Related Concept Videos
Chemical Agents for Microbial Control
Hand hygiene
Hand washing...
Leveling Effect and Non-Aqueous Acid-Base Solutions
The Leveling Effect of a Solvent
A generic acid (HA) reacts with the generic base (B-) to yield the corresponding conjugate base (A-) and conjugate acid (HB):
Weak Acid Solutions
Leveling Effect
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation: