Relationship between measures of central and general adiposity with aortic stiffness in the general population

Peter Wohlfahrt1, Virend K Somers2, Renata Cifkova3

  • 1Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA; International Clinical Research Center, St. Anne's University Hospital, Masaryk University, Brno, Czech Republic; Center for Cardiovascular Prevention of the First Faculty of Medicine, Charles University and Thomayer Hospital, Prague, Czech Republic; Department of Preventive Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic.

Atherosclerosis
|June 27, 2014
PubMed
Abstract

Related Concept Videos

Atherosclerosis II: Clinical Manifestations and Diagnostic Tests01:27

Atherosclerosis II: Clinical Manifestations and Diagnostic Tests

Atherosclerosis is a progressive disorder that leads to the thickening and narrowing of arterial walls due to plaque buildup. This condition can cause various symptoms depending on the arteries affected:Coronary Artery Disease (CAD): This condition affects the coronary arteries and may lead to chest pain (angina), shortness of breath (dyspnea), heart attacks, and other heart disease symptoms.Cerebrovascular Disease: This affects blood flow to the brain, causing transient ischemic attacks (TIAs)...
926
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
2.0K
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
1.4K
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
4.0K
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
760
Coronary Artery Disease I: Introduction01:30

Coronary Artery Disease I: Introduction

Coronary Artery Disease (CAD): An Overview with Scientific InsightsCoronary Artery Disease (CAD), often referred to as C-A-D, is a prevalent blood vessel disorder classified under the broader category of atherosclerosis. Atherosclerosis is a pathological process characterized by the hardening and narrowing of arteries due to the accumulation of atherosclerotic plaques. These plaques are composed of cholesterol, fatty substances, inflammatory cells, calcium, and fibrin, reducing blood flow to...
1.8K