Acute hemodialysis effects on doppler echocardiographic indices
Leila Abid1, Hajer Rekik, Fayçal Jarraya
1Cardiology Department, University Hedi Chaker Hospital, Medicine University of Sfax, Tunisia.
Abstract:
Conventional echocardiographic (ECHO) parameters of systolic and diastolic function of the left ventricular (LV) have been shown to be load dependent. However, the impact of pre-load reduction on tissue Doppler (TD) parameters of LV function is incompletely understood. To evaluate the effect of a single hemodialysis (HD) session on LV systolic and diastolic function using pulsed Doppler echocardiography and pulsed tissue Doppler imaging (TDI), we studied 81 chronic HD patients (40 males; mean age 52.4 ± 16.4 years) with these tools. ECHO parameters were obtained 30 min before and 30 min after HD. Fluid volume removed by HD was 1640 ± 730 cm³. HD led to reduction in LV end-diastolic volume (P <0.001), end-systolic volume (P <0.001), left atrium area (P <0.001), peak early (E-wave) trans-mitral flow velocity (P <0.001), the ratio of early to late Doppler velocities of diastolic mitral inflow (P <0.001) and aortic time velocity integral (P <0.001). No significant change in peak S velocity of pulmonary vein flow after HD was noted. Early and late diastolic (E') TDI velocities and the ratio of early to late TDI diastolic velocities (E'/A') on the lateral side of the mitral annulus decreased significantly after HD (P = 0.013; P = 0.007 and P = 0.008, respectively). Velocity of flow progression (Vp) during diastole was not affected by pre-load reduction. Pulmonary artery systolic pressure and the diameter of the inferior vena cava decreased significantly (P <0.001 and P <0.001, respectively) after HD. We conclude that most of the Doppler-derived indices of diastolic function are pre-load-dependent and velocity of flow progression was minimally affected by pre-load reduction in HD patients.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Hemodialysis II: Procedure and Complications
Hemodialysis III: Nursing Management
Hemodialysis I: Introduction
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Doppler Effect - II