Related Experiment Videos
[Use of a cup-shaped implant of polydioxanone in orbital-malar fractures]
D Cantaloube1, J M Rives, F Bauby
1Clinique de Chirurgie maxillo-faciale et de Stomatologie, H.I.A. Desgenettes, Lyon.
Revue De Stomatologie Et De Chirurgie Maxillo-Faciale
|January 1, 1989
Abstract:
Treatment of orbito-malar trauma has two priorities; restoration of the pelvi-orbital integrity and recovery of malar stability. Numerous techniques using various materials, whether or not of autologous origin, have been developed with this aim in mind. The authors report their experience with the PDS bioresorbable orbital prosthesis within the framework of orbito-malar trauma.