[Determination of kepone in water by liquid chromatography-tandem mass spectrometry]
Abstract:
An analytical procedure for the determination of kepone in water was described. Water samples were extracted by liquid-liquid extraction, and then cleaned-up. Chromatographic separation was performed on an Eclipse plus C18 column (100 mm x 2.1 mm, 3.5 microm) with gradient elution using acetonitrile and water at a flow rate of 0.3 mL/min. The target compounds were determined in multiple reaction monitoring (MRM) mode via negative electrospray ionization (ESI(-)) and quantified by isotopic-dilution technique. Results showed that kepone existed as diol form and hemiacetal in acetone/acetonitrile and methanol respectively, the structures of which were confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Due to the polar nature of kepone, it was difficult to be eluted during clean-up procedure and it may be decomposed during sulfuric acid washing. Therefore, it could not be analyzed together with the other organochlorine pesticides. The calibration curve showed good linearity in the range of 5-100 microg/L with correlation coefficient (r2) of 0.999. The limit of detection was 0.70 ng/L and the limit of quantification was 2.8 ng/L in water. The average recoveries when spiked at 5, 40 and 100 ng/L in water were 95.1%-98.9%, and the relative standard deviations (RSDs) were 3.85%-4.72%. The method can be used to the determination of kepone in water due to its high sensitivity, good recovery and reproducibility.
More Related Videos
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...