Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

286
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
286
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

401
Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
401
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

286
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
286
Computed Tomography01:10

Computed Tomography

8.0K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
8.0K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

803
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
803
Radiological Investigation I: X-ray and CT01:30

Radiological Investigation I: X-ray and CT

1.1K
Radiological investigations, including X-rays and computed tomography (CT) scans, are critical for diagnosing and evaluating various medical conditions. These imaging techniques provide valuable insights into the body's internal structures, aiding in the detection of abnormalities, assessment of disease progression, and development of treatment strategies. This article delves into two primary radiological investigations, chest X-rays and CT scans, outlining their purpose, procedures, and...
1.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Computer-Assisted Implant Planning: A Review of Data Registration Techniques.

The International journal of periodontics & restorative dentistry·2024
Same author

Merging Mandibular Virtual Datasets in Partially Edentulous Patients with a High Level of Scattering on CBCT Scans: A Technical Report.

The International journal of periodontics & restorative dentistry·2024
Same author

Maxillary sinus opacification after surgery in asymptomatic patients: Transient swelling of the sinus mucosa or graft dispersion into the maxillary sinus. A radiographic report of three cases after a follow-up period of at least 5 years.

International journal of oral implantology (Berlin, Germany)·2024
Same author

Risk indicators for gingival recession in the esthetic zone: A cross-sectional clinical, tomographic, and ultrasonographic study.

Journal of periodontology·2024
Same author

The impact of cone beam computer tomography field of view on the precision of digital intra-oral scan registration for static computer-assisted implant surgery: A CBCT analysis.

Clinical oral implants research·2022
Same author

Radiographic protrusion of dental implants in the maxillary sinus and nasal fossae: A multidisciplinary consensus utilising the modified Delphi method.

International journal of oral implantology (Berlin, Germany)·2022

Related Experiment Video

Updated: Jan 18, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.4K

Liabilities and risks of using cone beam computed tomography.

Bernard Friedland1, Dale A Miles2

  • 1Department of Oral Medicine, Infection and Immunity, Harvard School of Dental Medicine, 188 Longwood Avenue, Boston, MA 02115, USA.

Dental Clinics of North America
|July 5, 2014
PubMed
Summary

Practitioners using cone-beam computed tomography (CBCT) face medicolegal risks, including malpractice liability. Seek advice from malpractice carriers and dental boards before using CBCT scans and ensure competent interpretation.

Keywords:
Cone beam CTInterpretationLiabilityLicensingMalpracticeMedicolegalStandard of care

More Related Videos

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
10:23

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans

Published on: September 8, 2023

3.6K
Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
09:49

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization

Published on: December 2, 2013

10.7K

Related Experiment Videos

Last Updated: Jan 18, 2026

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.4K
Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
10:23

Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans

Published on: September 8, 2023

3.6K
Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
09:49

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization

Published on: December 2, 2013

10.7K

Area of Science:

  • Dental Radiology
  • Medical Law

Background:

  • Cone-beam computed tomography (CBCT) is increasingly utilized in dental practice.
  • The use of CBCT introduces potential medicolegal challenges for practitioners.

Purpose of the Study:

  • To inform dental practitioners about the medicolegal risks associated with CBCT.
  • To provide guidance on mitigating potential liabilities related to CBCT use.

Main Methods:

  • Review of potential medicolegal issues in CBCT adoption.
  • Analysis of licensing and malpractice concerns.

Main Results:

  • CBCT use presents significant medicolegal risks, including malpractice liability.
  • Practitioners must consult malpractice carriers before employing CBCT.
  • Competent interpretation of CBCT scans is essential.

Conclusions:

  • Awareness of medicolegal risks is crucial for practitioners using CBCT.
  • Consultation with malpractice carriers and dental boards is recommended.
  • Ensuring qualified interpretation of scans is vital to mitigate risks.