An updated systematic review and meta-analysis on impedance threshold devices in patients undergoing cardiopulmonary
G Biondi-Zoccai1, A Abbate2, G Landoni3
1Department of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy.
Introduction:
Uncertainty persists on the clinical impact of impedance threshold devices in out-of-hospital cardiac arrest. We conducted an updated systematic review on impedance threshold devices.
Methods:
Several databases were searched for studies testing the effectiveness of impedance threshold devices in patients with cardiac arrest. The primary endpoint was long-term survival.
Results:
Seven trials (11,254 patients) were included. In 4 studies (2,284 patients) impedance threshold devices were used with active compression-decompression-cardiopulmonary resuscitation, and in the others alone. Overall, impedance threshold devices did not impact on the rate of return of spontaneous circulation (odds ratio=1.17 [0.96-1.43], p=0.114), favorable neurologic outcome (odds ratio=1.56 [0.97-2.50], p=0.065), or long-term survival (odds ratio=1.22 [0.94-1.58], p=0.127). These analyses were fraught with heterogeneity (respectively, p=0.055, p=0.236, and p=0.011) and inconsistency (respectively, I-squared=51% , I-squared=27% , and I-squared=67%). Exploratory analysis showed that combined use of impedance threshold devices with active compression-decompression significantly increased the likelihood of return of spontaneous circulation (odds ratio=1.19 [1.00-1.40], p=0.045), favorable neurologic outcome (odds ratio=1.60 [1.14-2.25], p=0.006), and long-term survival (odds ratio=1.52 [1.11-2.08], p=0.009). The favorable impact of the interaction between impedance threshold devices and active compression-decompression was also confirmed at meta-regression analysis (respectively, b=0.195 [0.004-0.387], p=0.045, b=0.500 [0.079-0.841], p=0.018, b=0.413 [0.063-0.764], p=0.021).
Conclusions:
The evidence base on impedance threshold devices is apparently inconclusive, with a neutral impact on clinically relevant outcomes. However, exploratory analysis focusing on the combined use of impedance threshold devices with active compression-decompression suggests that this combo treatment may be useful to improve patient prognosis.
More Related Videos
08:25Impedance Pneumography for Minimally Invasive Measurement of Heart Rate in Late Stage Invertebrates
Published on: April 4, 2020
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation III: AED Use
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation IV: Pharmacological Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...