Related Experiment Video
Updated: Mar 26, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
The freestyle valve as a right ventricle to pulmonary artery conduit. A systematic review and meta-analysis
Ben Dunne1, Elizabeth Suthers1, Peter Xiao1
1Western Australian Cardiothoracic Research and Audit Group, Department of Cardiothoracic Surgery, Royal Perth Hospital, Perth, Western Australia.
Introduction:
Reconstruction of the right ventricular outflow tract is the most commonly performed valve repair/replacement procedure in congenital cardiac surgery. There is an ongoing shortage of homografts, and existing bioprosthetic options suffer from substantial rates of structural valve deterioration over time. The Medtronic Freestyle valve is used extensively in the aortic position, but little data is available on its performance in the pulmonary position.
Methods:
A systematic review and meta-analysis of primary studies reporting echocardiographic and clinical outcomes, including reintervention and functional status, associated with the Freestyle valve in the pulmonary position for both Ross and congenital surgery.
Results:
13 observational studies including 334 patients with a mean follow-up of 34 months (range 10-98 months) fulfilled the eligibility criteria and were included in the review. Structural valve deterioration occurred in 4.8% (95% confidence interval 0.8-10.6%) of patients. Reintervention was required in 1.1% (95% confidence interval 0.0-3.3%). Freedom from symptoms of heart failure occurred in 97.7% (94.6-99.7%). The results did not change substantially when analysed according to Ross or congenital surgery.
Conclusions:
The Freestyle valve performs well at short-term follow-up and provides a viable alternative when homografts are unavailable. Further long-term studies are required to better assess its role in right ventricular outflow tract reconstruction.
More Related Videos
09:40Induction of Right Ventricular Failure by Pulmonary Artery Constriction and Evaluation of Right Ventricular Function in Mice
Published on: May 13, 2019
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Cardiac Catheterization II: Right Heart Catheterization
Overview of Pulmonary Circulation
The process begins with the right ventricle of the heart pumping deoxygenated blood into the pulmonary trunk. This large vessel extends about 5 centimeters before splitting into the left and right pulmonary arteries. These arteries...
Mitral Stenosis I: Introduction
Overview of Systemic and Pulmonary Circulation
The oxygenated blood is sent...
Chambers of the Heart
Deoxygenated blood from the body is received in the right...