Related Experiment Video
Updated: Apr 26, 2026

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Slow and fast lung compartments in cystic fibrosis measured by nitrogen multiple-breath washout
P M Gustafsson1, P D Robinson2, M Gilljam3
1Department of Pediatrics, Central Hospital, Skövde, Sweden; The Sahlgrenska Academy at the University of Gothenburg, Gothenburg, Sweden; per.gustafsson@vgregion.se.
Abstract:
Imaging studies describe significant ventilation defects across a wide range of cystic fibrosis (CF) related lung disease severity. These are unfortunately poorly reflected by phase III slope analysis-derived Scond and Sacin from multiple-breath washout (MBW). Methodology extending previous two-lung compartment model-based analysis is presented describing size and function of fast- and slow-ventilating lung compartments from nitrogen (N2) MBW and correlation to obstructive lung disease severity. In 37 CF subjects (forced expiratory volume in 1 s [FEV1] mean [SD] 84.8 [19.9] % predicted; abnormal lung clearance index [LCI] in 36/37, range 7.28-18.9) and 74 matched healthy controls, volume and specific ventilation of both fast and slowly ventilated lung compartments were derived from N2-based MBW with commercial equipment. In healthy controls lung emptying was characterized by a large compartment constituting 75.6 (8.4)% of functional residual capacity (FRC) with a specific ventilation (regional alveolar tidal volume/regional lung volume) of 13.9 (3.7)% and a small compartment with high specific ventilation (48.4 [15.7]%). In CF the slowly ventilated lung compartment constituted 51.9(9.1)% of FRC, with low specific ventilation of 5.3 (2.4)%. Specific ventilation of the slowly ventilated lung compartment showed stronger correlation with LCI (r2 = 0.70, P < 0.001) vs. Sacin (r2 = 0.44, P < 0.001) or Scond (no significant correlation). Overventilation of the fast lung compartment was no longer seen in severe CF lung disease. Magnitude and function of under- and overventilated lung volumes can be derived from routine N2 MBW in CF. Reported values agree with previous modelling-derived estimates of impaired ventilation and offer improved correlation to disease severity, compared with SnIII analysis.
More Related Videos
08:23Author Spotlight: Advancing Lung Disease Research with Free-Breathing Hyperpolarized Xenon-129 MRI
Published on: November 10, 2023
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Lung Capacity
External and Internal Respiration
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...