Proximal humeral fractures: an understanding of the ideal plate positioning
Pedro José Labronici1, Rodrigo Pires e Albuquerque, Vinícius Schott
1Department of Orthopaedic Surgery, Federal Fluminense University, Niterói, Rio de Janeiro, Brazil.
Purpose:
The present study aims to evaluate if the bicipital groove can be used as a parameter for ideal plate positioning in proximal humeral fixation applying locking compression plate.
Method:
The authors questioned whether the bicipital groove can be used as a parameter for ideal plate positioning applying locking compression plate for proximal humeral fractures. A method using the bicipital groove as the main parameter was developed using computed tomography scan (CT-scan). Seventy shoulders presenting fracture absence were used to calculate proper plate positioning, allowing the largest area for locked screw placement into the humeral head. Intraclass correlation coefficient and Bland and Altman graphics calculated intra-observer reliability for CT-scan evaluation.
Results:
All observers presented satisfactory plate positioning using this method. The mean differences for observers were close to zero, suggesting high interobserver reproducibility. A significant (p <0.0001) intra-observer agreement existed for the three evaluators. Observer 2 agreement was the strongest (ICC = 0.98), showing almost perfect reproducibility measurement, followed by observer 3 (ICC = 0.84) with good reproducibility, and lastly observer 1 demonstrated moderate degree agreement (ICC = 0.47).
Conclusion:
Considering the CT-scan analysis, the bicipital groove can be used as a parameter for ideal plate positioning in proximal humeral fractures. This method demonstrated satisfactory intra-observer reproducibility. Adopting this method, longer and better distributed screw placement provides more stable fixation for proximal humeral fractures.
More Related Videos
06:59Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
Published on: August 14, 2018
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Humerus