Related Experiment Video
Updated: Apr 26, 2026

An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
Assessment of self-help methods to reduce potential exposure to radiological contamination after a large-scale
Emily Snyder1, John Drake, John Cardarelli
1*U.S. EPA Office of Research and Development's National Homeland Security Research Center, 109 TW Alexander Drive, Research Triangle Park, NC 27711; †U.S. EPA Office of Research and Development's National Homeland Security Research Center, 26 West Martin Luther King Drive, Cincinnati, OH 45268; ‡U.S. EPA Office of Solid Waste and Emergency Response Office of Emergency Management's Consequence Management Advisory Team, 4900 Olympic Blvd, Erlanger, KY 41018; §Idaho National Laboratory, Idaho National Laboratory, 2525 Fremont Ave., Idaho Falls, ID 83415; **Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352; ††Battelle Memorial Institute, 505 King Avenue, Columbus, OH 43201.
Abstract:
After the release of radioactive materials from a large radiological dispersal device (e.g., dirty bomb), improvised nuclear detonation, or nuclear power plant accident, up to hundreds of square miles may be contaminated. A portion of this area will be evacuated; however, people living in the portion that is not evacuated yet is still contaminated with low-levels of radioactive contamination will be asking for ways they can reduce their exposure. Whether cleaning activities can significantly reduce exposure is not fully understood. In this effort, the ability of cleaning activities to remove cesium (137Cs) was studied. The removal efficacy of cleaning with a commercial product, Simple Green®, was compared to cleaning with water for hard surfaces typically seen in residences. The removal efficacy of laundering fabric material surfaces was also determined for a range of conditions (e.g., fabric material type, wash temperature). During these studies, assessments of the implications of these activities (e.g., cross-contamination, resulting waste streams) were also completed. Simple Green and water were effective for removing 137Cs from plastic laminate and vinyl flooring (93.4-96.8%) but were not effective for removing 137Cs from painted wallboard and wood (7.3-68.1%). It was also determined that there was no significant difference between the two cleaners on all of the surfaces, except plastic laminate, for which Simple Green was slightly more effective. Laundering was effective for removing 137Cs contamination from polyester and cotton swatches and cotton comforters (up to 96.8% in the single swatch testing).
More Related Videos
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Prevention of Further Absorption of Poison
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

