A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Randomized controlled trial of inhaled nitric oxide for the treatment of microcirculatory dysfunction in patients
Stephen Trzeciak1, Lindsey J Glaspey, R Phillip Dellinger
11Division of Critical Care Medicine, Department of Medicine, Cooper University Hospital, Cooper Medical School of Rowan University, Camden, NJ. 2Department of Critical Care Medicine and The Safar Center for Resuscitation Research, University of Pittsburgh, Pittsburgh, PA. 3Department of Emergency Medicine, Cooper University Hospital, Cooper Medical School of Rowan University, Camden, NJ. 4Division of Cardiovascular Disease, Department of Medicine, Cooper University Hospital, Cooper Medical School of Rowan University, Camden, NJ.
Objectives:
Sepsis treatment guidelines recommend macrocirculatory hemodynamic optimization; however, microcirculatory dysfunction is integral to sepsis pathogenesis. We aimed to test the hypothesis that following macrocirculatory optimization, inhaled nitric oxide would improve microcirculation in patients with sepsis and that improved microcirculation would improve lactate clearance and multiple organ dysfunction.
Design:
Randomized, sham-controlled clinical trial.
Setting:
Single urban academic medical center.
Patients:
Adult patients with severe sepsis and systolic blood pressure less than 90 mm Hg despite intravascular volume expansion and/or serum lactate greater than or equal to 4.0 mmol/L.
Interventions:
After achievement of macrocirculatory resuscitation goals, we randomized patients to 6 hours of inhaled nitric oxide (40 ppm) or sham inhaled nitric oxide administration. We administered study drug via a specialized delivery device that concealed treatment allocation so that investigators and clinical staff remained blinded.
Measurements And Main Results:
We performed sidestream dark-field videomicroscopy of the sublingual microcirculation prior to and 2 hours after study drug initiation. The primary outcome measure was the change in microcirculatory flow index. Secondary outcomes were lactate clearance and change in Sequential Organ Failure Assessment score. We enrolled 50 patients (28 of 50 [56%] requiring vasopressor agents; 15 of 50 [30%] died). Although inhaled nitric oxide significantly raised plasma nitrite levels, it did not improve microcirculatory flow, lactate clearance, or organ dysfunction. In contrast to previous studies conducted during the earliest phase of resuscitation, we found no association between changes in microcirculatory flow and lactate clearance or organ dysfunction.
Conclusions:
Following macrocirculatory optimization, inhaled nitric oxide at 40 ppm did not augment microcirculatory perfusion in patients with sepsis. Further, we found no association between microcirculatory perfusion and multiple organ dysfunction after initial resuscitation.
More Related Videos
08:23Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Nitric Oxide Signaling Pathway
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...