Related Experiment Video
Updated: Apr 26, 2026

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Prior hematologic conditions carry a high morbidity and mortality in patients supported with continuous-flow left
Justin Fried1, Allison P Levin1, Kanika M Mody1
1Division of Cardiology, Department of Medicine, Columbia University Medical Center, New York, New York.
Background:
Mechanical support leads to an increased risk of both bleeding and thrombotic events, but little is known about the risk of device support in patients with a baseline predisposition to these events. The aim of this study was to examine outcomes among patients with baseline hematologic conditions who underwent continuous-flow LVAD implantation (CF-LVAD).
Methods:
We retrospectively reviewed records of 286 patients who underwent CF-LVAD implantation at the Columbia University Medical Center between April 2008 and December 2013. Patients diagnosed with the following hematologic conditions were enrolled: idiopathic thrombocytopenic purpura (ITP); Factor V Leiden; elevated Factor VIII; heparin-induced thrombocytopenia (HIT); or undefined hypercoagulable state.
Results:
Of the 286 CF-LVAD patients implanted during the study period, 12 were considered to have a significant hematologic condition predisposing them to either bleeding or thrombotic events. The study included 5 patients with ITP, 1 with Factor V Leiden, 1 with elevated Factor VIII, 2 with HIT and 3 patients with undefined hypercoagulable state. Patients were supported for a total of 168.46 months, with a median of 10.76 months (IQR 4.78 to 21.36 months). There was a high frequency of thrombotic (0.57 event per patient-year), neurologic (0.36 event per patient-year) and bleeding (0.64 event per patient-year). Actuarial survival rates at 6 and 12 months were 81.8%, but fell to 49% at 2 years.
Conclusions:
Patients with a history of prior hematologic conditions are at high risk for bleeding, thrombotic and neurologic events during device support, leading to early mortality. This case series questions the benefit of CF-LVAD in these patients and the appropriate management with regard to anti-coagulation. Further studies on the outcomes of these patients are warranted.
More Related Videos
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure VI: Adjunct Therapies
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Heart Failure V: Medical Management
Heart Failure II: Pathophysiology