L E McMahon1, K N Johnson2, D E Jaroszewski3
1Phoenix Children's Hospital Department of Surgery, University of Arizona, and Mayo Clinic, Arizona.
Background:
Minimally invasive repair of pectus excavatum has become an established method for repair of pectus excavatum. Bar displacement or rotation remains the most common complication of this repair requiring return to the operating room.
Methods:
Retrospective review of all patients at a single institution who underwent repair of pectus excavatum using FiberWire for bar stabilization between December 2009 and March 2013 was undertaken.
Results:
93 patients underwent minimally invasive pectus repair using FiberWire during the study period. The patients included 73 males and 20 females, with an average age of 14.6years (range 7-21years). Mean operative time was 102minutes (range 56-198minutes). No patients developed wound complications, two patients developed pain because of bar migration and required return to the OR, and no patients had recurrence of their pectus defect because of bar migration during the study period. Median length of follow-up was 17months (range 3-36months).
Conclusion:
Stabilization of pectus bars using circumferential rib fixation with FiberWire at multiple points on both sides of the bar appears to be effective in preventing bar rotation and displacement, and requires minimal change to the operation as it has been previously described. Early experience shows a low rate of complications.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
05:25Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears
Published on: January 23, 2026
Related Concept Videos
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...