Shikhar Agarwal1, Akhil Parashar1, Stephen G Ellis1
1From the Section of Interventional Cardiology, Department of Cardiovascular Medicine, Heart and Vascular Institute (S.A., S.G.E., F.A.H., E.L., E.M.T., S.R.K.), and Department of Internal Medicine (A.P.), Cleveland Clinic, OH.
Background:
X-ray use in the catheterization laboratory is guided by the principle of as low as reasonably achievable. In accordance with this principle, we reduced the default fluoroscopic frame rate from 10 to 7.5 frames/s and increased the emphasis on the use of low-dose acquisition starting January 1, 2013. We aimed to study the impact of these measures on the total air kerma during diagnostic catheterization (DC) and percutaneous interventions (PCI).
Methods And Results:
Propensity matching based on age, sex, body surface area, total fluoroscopy time, and total acquisition time was used to select matched patients for 2012 and 2013, further stratified by DC or PCI. The total air kerma was subsequently compared between 2012 and 2013, separately for DC and PCI. Median total air kerma during DC in 2013 was 625 mGy, which was significantly lower than the corresponding values in 2012 (median, 798 mGy; P<0.001). Similarly, median total air kerma during PCI in 2013 was 1675 mGy, which was significantly less than corresponding values in 2012 (median 2463 mGy, P<0.001). On comparison of air kerma rates between corresponding projections in 2 years, we observed a significant reduction in fluoroscopy- and acquisition-based air kerma rates in 2013, after institution of radiation reduction measures in all projections.
Conclusions:
With reduction in the default fluoroscopic frame rate and a greater use of low-dose acquisition, there has been a marked reduction in the total air kerma and air kerma rates for DC and PCI.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
08:30X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization III: Left Heart Catheterization
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...