Related Experiment Video
Updated: Apr 26, 2026

Dynamic Navigation for Dental Implant Placement
Published on: September 13, 2022
Accuracy of chairside-milled CAD/CAM drill guides for dental implants
Purpose:
To describe a chairside method for producing implant guides based solely on digital data and present a first assessment of in vitro accuracy on plaster models.
Material And Methods:
Twenty-four implants were planned and pilot drillings were performed according to a new protocol, which is based on the registration of CBCT and CAD/CAM data. Chairside-milled one-piece drill guides were used to transfer the virtual plan into reality. Accuracy measurements were acquired.
Results:
Chairside-milled drill guides were successfully fabricated and accuracy for pilot drillings was between 0.17 and 1.3 mm.
Conclusion:
Within the limits of this experimental study, chairside-milled drill guides are feasible and do not require any preparation before CBCT scanning.