Autocalibration of accelerometer data for free-living physical activity assessment using local gravity and
Vincent T van Hees1, Zhou Fang2, Joss Langford3
1MoveLab, Institute of Cellular Medicine, Newcastle University, Newcastle, United Kingdom; Medical Research Council Epidemiology Unit, University of Cambridge, Cambridge, United Kingdom.
Abstract:
Wearable acceleration sensors are increasingly used for the assessment of free-living physical activity. Acceleration sensor calibration is a potential source of error. This study aims to describe and evaluate an autocalibration method to minimize calibration error using segments within the free-living records (no extra experiments needed). The autocalibration method entailed the extraction of nonmovement periods in the data, for which the measured vector magnitude should ideally be the gravitational acceleration (1 g); this property was used to derive calibration correction factors using an iterative closest-point fitting process. The reduction in calibration error was evaluated in data from four cohorts: UK (n = 921), Kuwait (n = 120), Cameroon (n = 311), and Brazil (n = 200). Our method significantly reduced calibration error in all cohorts (P < 0.01), ranging from 16.6 to 3.0 mg in the Kuwaiti cohort to 76.7 to 8.0 mg error in the Brazil cohort. Utilizing temperature sensor data resulted in a small nonsignificant additional improvement (P > 0.05). Temperature correction coefficients were highest for the z-axis, e.g., 19.6-mg offset per 5°C. Further, application of the autocalibration method had a significant impact on typical metrics used for describing human physical activity, e.g., in Brazil average wrist acceleration was 0.2 to 51% lower than uncalibrated values depending on metric selection (P < 0.01). The autocalibration method as presented helps reduce the calibration error in wearable acceleration sensor data and improves comparability of physical activity measures across study locations. Temperature ultization seems essential when temperature deviates substantially from the average temperature in the record but not for multiday summary measures.
Related Concept Videos
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Variation in Acceleration due to Gravity near the Earth's Surface
The difference between the true and apparent weights is proportional to the square of the Earth's...
Acceleration due to Gravity on Earth
The acceleration of an object close to the Earth, because of the Earth's gravitational pull, is called the acceleration due to gravity. It is...
Acceleration due to Gravity on Other Planets
Astronomical observations are thus used to measure the acceleration due to gravity on other planets. This can be determined by observing the effect of a planet's gravity on objects close to it. The crucial factor that helps in this...
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Application of Linearization and Approximation