Quality assessment of INAA data for small-sized environmental reference samples
Wanna Wimolwattanapun1, Supamatthree Bunprapob, Mang Dung Ho
1Thailand Institute of Nuclear Technology.
Summary
Instrumental neutron activation analysis (INAA) accurately determined trace elements in milligram samples. Certified reference materials (CRMs) showed varying lab performance, but are suitable for small-scale INAA.
Area of Science:
- Analytical Chemistry
- Nuclear Chemistry
- Materials Science
Background:
- Accurate elemental analysis is crucial for materials characterization.
- Certified Reference Materials (CRMs) are essential for quality assurance and control (QA/QC).
- Analyzing small sample sizes presents unique challenges in elemental determination.
Purpose of the Study:
- To assess the accuracy and precision of instrumental neutron activation analysis (INAA) for trace elements in small sample aliquots (1-2 mg).
- To evaluate the suitability of NIES No. 8 and NIST 1632c CRMs for mg-scale INAA.
- To compare the analytical capabilities of different laboratories using established QA/QC metrics.
Main Methods:
- Instrumental Neutron Activation Analysis (INAA), including comparative and k0-INAA methods.
- Analysis of two CRMs (NIES No. 8 and NIST 1632c) using 1-2 mg aliquots.
- Repeated analysis (>10 times per CRM) across four participating laboratories.
- Quality assurance and control (QA/QC) assessment using z-scores and zeta scores.
Main Results:
- Successful determination of 16-18 minor and trace elements in mg-scale CRM aliquots.
- Significant variations in analytical performance were observed among participating laboratories.
- Z-scores and zeta scores indicated differences in laboratory analytical capabilities.
Conclusions:
- The studied CRMs (NIES No. 8 and NIST 1632c) are validated for use as reference materials in mg-scale INAA.
- The findings highlight the importance of robust QA/QC protocols when analyzing small sample sizes.
- INAA is a viable technique for precise trace element determination in microgram quantities.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
1.3K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.3K
Atomic Emission Spectroscopy: Overview
3.0K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
3.0K
Atomic Emission Spectroscopy: Lab
866
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
866