Evaluation of the Macular Choroidal Thickness Using Spectral Optical Coherence Tomography in Pseudoexfoliation
Hasan A Bayhan1, Seray Aslan Bayhan, İzzet Can
1Ophthalmology Department, Faculty of Medicine, Bozok University, Yozgat, Turkey.
Purpose:
To evaluate the choroidal thickness (CT) in pseudoexfoliative (PEX) glaucoma and age-matched healthy subjects using spectral optical coherence tomography (SD-OCT).
Patients And Methods:
In this prospective study, 32 eyes of 32 PEX glaucoma patients and 30 eyes of 30 age-matched healthy subjects were enrolled. The CT is measured perpendicularly (from the outer edge of the hyperreflective retinal pigment epithelium to the inner sclera) at the fovea, and 1.5 mm temporal, 3.0 mm temporal, 1.5 mm nasal, and 3.0 mm nasal to the fovea using SD-OCT (RTVue-100).
Results:
The groups were similar regarding the mean age and axial length values (both, P>0.05). The CT measurements were 182.12 ± 39.88 and 201.56 ± 32.00 μm at 1.5 mm nasal to the fovea (P=0.039), and 126.47 ± 32.12 and 146.60 ± 31.37 μm at 3.0 mm nasal to the fovea (P=0.015) in the PEX glaucoma and control groups, respectively. There were no significant differences in the subfoveal and temporal CT measurements among the 2 groups (all, P>0.05).
Conclusions:
The findings of this study indicate that PEX glaucoma causes significant thinning in the nasal choroid. Thus, measuring the CT with SD-OCT may be the way of better clarification of the relationship between PEX and glaucomatous optic neuropathy.
More Related Videos
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
03:47Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...