Related Experiment Video
Updated: Apr 25, 2026

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Qualitative and quantitative analysis of a group of volatile organic compounds in biological samples by HS-GC/FID:
C Monteiro1, J M Franco1, P Proença1
1National Institute of Legal Medicine and Forensic Sciences-Centre Branch, Largo da Sé Nova, 3000-213 Coimbra, Portugal; CENCIFOR-Forensic Sciences Centre, Largo da Sé Nova, 3000-213 Coimbra, Portugal.
Abstract:
A simple and sensitive procedure, using n-propanol as internal standard (IS), was developed and validated for the qualitative and quantitative analysis of a group of 11 volatile organic substances with different physicochemical properties (1-butanol, 2-propanol, acetaldehyde, ethyl acetate, acetone, acetonitrile, chloroform, diethyl ether, methanol, toluene and p-xylene) in whole blood, urine and vitreous humor. Samples were prepared by dilution with an aqueous solution of internal standard followed by Headspace Gas Chromatography with a Flame-ionization Detector (HS GC-FID) analysis. Chromatographic separation was performed using two capillary columns with different polarities (DB-ALC2: 30m×0.320mm×1.2μm and DB-ALC1: 30m×0.320mm×1.8μm), thus providing a change in the retention and elution order of volatiles. This dual column confirmation increases the specificity, since the risk of another substance co-eluting at the same time in both columns is very small. The method was linear from 5 to 1000mg/L for toluene and p-xylene, 50-1000mg/L for chloroform, and 50-2000mg/L for the remaining substances, with correlation coefficients of over 0.99 for all compounds. The limits of detection (LOD) ranged 1 to 10mg/L, while the limits of quantification (LOQ) ranged from 2 to 31mg/L. The intra-day precision (CV<6.4%), intermediate precision (CV<7.0%) and accuracy (relative error ±10%) of the method were in conformity with the criteria normally accepted in bioanalytical method validation. The method developed has been applied to forensic cases, with the advantages that it uses a small sample volume and does not require any extraction procedure as it makes use of a headspace injection technique.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Volatilization
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...