Related Experiment Video
Updated: Apr 25, 2026

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Charge-based characterisation of high-molecular-weight glutenin subunits from common wheat by capillary isoelectric
Bolesław P Salmanowicz1, Monika Langner1, Sławomir Franaszek1
1Institute of Plant Genetics of the Polish Academy of Science, Strzeszyńska Str. 34, 60-479 Poznań, Poland.
Abstract:
In this study, the capillary isoelectric focusing (CIEF) method for the separation and charge characterisation of the heterogeneity of high molecular-weight-glutenin subunits (HMW-GS) in common wheat (Triticum aestivum L.) using linear polyacrylamide (LPA) and polyvinyl alcohol (PVA) coated capillaries was developed. Particularly good repeatability and well-resolved charge isoform profiles were obtained by introducing a mixture of carrier ampholytes (pH 3-10 and pH 5-8), a high concentration of urea (6M) and SB3-12 as detergent in a sample solution during separation in a PVA-coated capillary. One major and one or two minor isoforms were observed for the individual HMW-GS. These isoforms were satisfactorily separated using a pH gradient into two groups: y-type isoforms and x-type isoforms encoded by the Glu-B1 locus with shorter migration times and remaining x-type isoforms with longer times. The method produced from eight to twelve isoforms of wheat HMW-GS with pI points in the range of 4.72-6.98. Generally, the minor isoforms were more acidic compared with the major isoform. The y-type subunits had an approximately neutral character (pI 6.70-6.98); however, x-types showed a weakly acidic character (pI 4.72-5.23), with the exception of subunits encoded by the Glu-B1 locus. The isoelectric point peak profiles were compared with capillary zone electrophoresis (CZE) electropherograms. Generally, the number of detected isoforms for the particular HMW-GS detected using both methods were similar.
More Related Videos
09:57Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing IEF Method
Published on: June 14, 2020
05:45Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...