A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Ionic liquid intercalated clay sorbents for micro solid phase extraction of steroid hormones from water samples with
Can Aftafa1, Füsun Okçu Pelit1, Esra Evrim Yalçinkaya1
1Ege University, Faculty of Science, Department of Chemistry, 35100 Bornova, İzmir, Turkey.
Abstract:
Clay material plays an important role in the transport and retention of many compounds in the soil, therefore, clay based sorbents are promising alternatives for selective sorption of organic pollutants. In the present work, different chain length ionic liquids (ILs) namely, 1-methyl-3-octyl-imidazolium bromide, 1-methyl-3-undecyl-imidazolium bromide and 1-methyl-3-octadecyl-imidazolium bromide were intercalated in the galleries of montmorillonite (MMT) clay. Then, this novel nanofiller surface was utilized in micro extraction of estrogenic hormones for the first time. A fast procedure where sonication-assisted emulsification microextraction combined with vortex assisted micro-solid phase extraction (μ-SPE) was developed for the LC-MS/MS analysis of estrone (E1), 17β-estradiol (E2), estriol (E3) and ethynylestradiol (EE2). The parameters related to the μ-SPE procedure namely; pH, sorbent amount, extraction solvent type and volume, sonication and vortex time, sample volume and salt effect on the extraction efficiency were screened by applying Plackett-Burmann design. The selected parameters were then optimized by using Box-Behnken design. The method was validated for the determination of estrogenic hormone residues in river water samples. Linear calibration plots were obtained for all hormones whose regression coefficients were larger than 0.98. RSD values were found less than 10% for three levels of concentration. LOD levels were calculated as; 0.012, 0.062, 0.018 and 0.693 ng L(-1) for E1, E2, E3 and EE2, respectively. Recovery values were calculated in the range of 86.9-97.7%. Considering large sample volumes required for attaining low limits of these hormones, present method provides an ease for analyst as 10 mL of the sample is adequate for achieving the same sensitivity.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Types of Detectors