Poor agreement between dialysis unit blood pressure and interdialytic ambulatory blood pressure
Wenjin Liu1, Jing Niu, Chunsun Dai
1Center for Kidney Disease, 2nd Affiliated Hospital, Nanjing Medical University, Nanjing, China.
Abstract:
Although ambulatory blood pressure (ABP) monitoring (ABPM) is often considered to have an advantage over dialysis unit blood pressure (BP) in dialysis patients, the exact relationship between these two measurements of BP has not been well determined. In a cohort of 90 Chinese dialysis patients, agreement between dialysis unit BP (predialysis and postdialysis BP) and interdialytic ABP was evaluated using Bland-Altman plots and Lin's concordance correlation coefficient for quantitative analysis, and inter-rater agreement (κ) for qualitative analysis. Limits of agreement between dialysis unit BP and ABP were wide (predialysis systolic BP: -33.5 to 20.9 mm Hg; predialysis diastolic BP: -22.2 to 11.9 mm Hg; postdialysis systolic BP: -25.4 to 26.5 mm Hg; postdialysis diastolic BP: -18.4 to 12.3 mm Hg). Lin's concordance correlation coefficient exhibited a poor agreement with concordance correlation coefficients of 0.75, 0.81, 0.64, and 0.75 for predialysis systolic BP, postdialysis systolic BP, predialysis diastolic BP, and postdialysis diastolic BP, respectively. When BP level was classified into quartiles, an increasing trend for incorrect classification rate was observed with deleterious hypertension, with the highest value in grade 3 hypertension (100% and 75.0% for predialysis and postdialysis BP, respectively). Therefore, these data suggest that agreement between dialysis unit BP and interdialytic ABP is poor in Chinese dialysis patients, and the bias for patients with higher degree of hypertension is more prominent.
More Related Videos
04:37Improved Home Blood Pressure Control by CT-guided Ozone-mediated Renal Denervation for Patients with Resistant Hypertension
Published on: June 6, 2025
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Hemodialysis III: Nursing Management
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...