Related Experiment Video
Updated: Apr 25, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Research on a novel two-stage direct current hybrid circuit breaker
Yifei Wu1, Yi Wu1, Mingzhe Rong1
1State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, People's Republic of China.
Abstract:
The DC hybrid circuit breaker based on high-speed switch (HSS) and parallel connected capacitor has been widely applied in the fault current breaking of DC system. However, when the current is commutated from HSS to the capacitor according to single-stage operation, the capacitor has to absorb a large amount of energy stored in the system inductance within very short time. Meanwhile, a high over-voltage rate of rise is especially prone to be produced between the contacts of HSS, which will lead to a failed breaking. As a result, a novel DC hybrid circuit breaker based on the two-stage operation is proposed and analyzed in this paper. By controlling the thyristors in the commutation branches, the fault current is fast commutated into the capacitor, which can not only realize the arcless open of HSS, but also decrease the over-voltage rate of rise significantly in comparison to the traditional single-stage operation. The simulation model of fault current breaking under different conditions in 10 kV medium voltage DC system is constructed. The simulated over-voltages of single-stage and two-stage operations in the case of fault current breaking are compared and analyzed. Finally, the fault current breaking test in the two-stage operation is investigated experimentally, which validates the feasibility and effectiveness of the simulation model well.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
Related Concept Videos
Circuit Breaker and Fuse Selection
In high-voltage systems,...
Directional Relays
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Power System Three-Phase Short Circuits
Differential Relays
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...