Related Experiment Video
Updated: Apr 24, 2026

Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Performance of ACR Lung-RADS in a clinical CT lung screening program
Brady J McKee1, Shawn M Regis2, Andrea B McKee2
1Department of Radiology, Lahey Hospital & Medical Center, Burlington, Massachusetts.
Purpose:
The aim of this study was to assess the effect of applying ACR Lung-RADS in a clinical CT lung screening program on the frequency of positive and false-negative findings.
Methods:
Consecutive, clinical CT lung screening examinations performed from January 2012 through May 2014 were retroactively reclassified using the new ACR Lung-RADS structured reporting system. All examinations had initially been interpreted by radiologists credentialed in structured CT lung screening reporting following the National Comprehensive Cancer Network's Clinical Practice Guidelines in Oncology: Lung Cancer Screening (version 1.2012), which incorporated positive thresholds modeled after those in the National Lung Screening Trial. The positive rate, number of false-negative findings, and positive predictive value were recalculated using the ACR Lung-RADS-specific positive solid/part-solid nodule diameter threshold of 6 mm and nonsolid (ground-glass) threshold of 2 cm. False negatives were defined as cases reclassified as benign under ACR Lung-RADS that were diagnosed with malignancies within 12 months of the baseline examination.
Results:
A total of 2,180 high-risk patients underwent baseline CT lung screening during the study interval; no clinical follow-up was available in 577 patients (26%). ACR Lung-RADS reduced the overall positive rate from 27.6% to 10.6%. No false negatives were present in the 152 patients with >12-month follow-up reclassified as benign. Applying ACR Lung-RADS increased the positive predictive value for diagnosed malignancy in 1,603 patients with follow-up from 6.9% to 17.3%.
Conclusions:
The application of ACR Lung-RADS increased the positive predictive value in our CT lung screening cohort by a factor of 2.5, to 17.3%, without increasing the number of examinations with false-negative results.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...