Related Experiment Video
Updated: Apr 24, 2026

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Effect of EDTA preparations on rotary root canal instrumentation
Evan R Whitbeck1, Kelli Swenson1, Patricia A Tordik1
1Naval Postgraduate Dental School, Bethesda, Maryland.
Introduction:
The aim of this study was to evaluate whether rotary instrumentation using saline, EDTA 17% solution, or RC-Prep (Premier Dental, Philadelphia, PA) resulted in differences in root canal transportation. The secondary objective was to assess if instrumentation using these agents caused changes in the working length and canal volume.
Methods:
Moderately curved mesiobuccal roots of 24 maxillary molars were standardized in length and randomized into 1 control and 2 experimental groups. The canals were instrumented with 0.04 taper rotary files to size #30. All groups were irrigated with saline. Group 1 was also irrigated using EDTA 17% solution (Pulpdent Corp, Watertown, MA), and in group 2, RC-Prep was used. X-ray micro-computed tomographic scans and working length measurements were made before and after instrumentation. Three-dimensional models were created from the pre- and postinstrumentation scan data and compared for volume changes. Centroid points were calculated in cross-sectional slices of the canals, and transportation was determined by measuring the distance between the pre- and postinstrumentation points. The data were analyzed with 1-way analysis of variance (α = 0.05) and the Tukey post hoc test.
Results:
Less transportation was observed in group 2 than in group 1 (P = .001) and the control group (P = .014). Transportation in group 1 and the control group was not significantly different. Canal volume in group 1 was increased relative to group 2 (P = .004) and the control group (P = .022). No significant differences in the working length were observed.
Conclusions:
The use of chelating agents during root canal instrumentation did not significantly increase apical transportation.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
EDTA: Auxiliary Complexing Reagents
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
EDTA: Chemistry and Properties
EDTA: Indirect and Alkalimetric Titration
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...