Plakoglobin immunolocalization as a diagnostic test for arrhythmogenic right ventricular cardiomyopathy
Simon Ermakov1, Philip C Ursell, Colleen J Johnson
1School of Medicine, University of California - San Francisco, San Francisco, California.
Background:
A recent study using an anti-plakoglobin antibody and immunofluorescence methods in endomyocardial tissue specimens found that a marked reduction in plakoglobin staining was highly sensitive and specific for the diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC). The purpose of our study was to determine the diagnostic utility of plakoglobin immunolocalization using more standard immunoperoxidase methods suitable for clinical laboratories.
Methods:
Between January 2007 and October 2010, all patients at our center with suspected ARVC underwent noninvasive and genetic testing, right ventricular (RV) angiography, electrophysiologic studies, and endomyocardial biopsy from the RV septum. Several studies using anti-plakoglobin antibodies were performed using standard immunoperoxidase methods at concentrations of 1:50,000 and 1:75,000 after serial dilutions.
Results:
Among 16 patients, nine patients fulfilled the clinical criteria for ARVC, and seven patients were found to have other cardiac diagnoses. In the initial study (1:50,000) only one of nine ARVC patients showed reduced plakoglobin signal while the others had normal staining. On repeat staining (1:75,000), reduced signal was observed in three of five of the ARVC patients compared to none in controls (four patients did not have adequate tissue for the repeat experiment).
Conclusion:
These results confirm that abnormal plakoglobin staining can differentiate biopsies from patients with ARVC from those with other myopathies, but with low sensitivity. Further, each specimen must be studied at a particular concentration due to variable antibody reactivity. The necessity for such fine-tuning of the reaction, as well as the subjectivity involved in interpretation of the results, would make this method difficult to utilize in routine hospital laboratories.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
08:52Author Spotlight: Developing a Translational Model for Atrial Fibrillation Research Across Species
Published on: November 21, 2023
Related Concept Videos
Cardiomyopathy IV: Restrictive Cardiomyopathy
Myocarditis II: Clinical Features and Diagnostic Tests
Dysrhythmias V: Evaluating Dysrhythmias
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies