Related Experiment Video
Updated: Apr 24, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
[Graft replacement under percutaneous cardiopulmonary system for traumatic aortic rupture with multiple injuries]
Shuichi Okada1, Masahiko Ezure, Tatsuo Kaneko
1Division of Cardiovascular Surgery, Gunma Prefectural Cardiovascular Center, Maebashi, Japan.
Abstract:
We report a case of traumatic aortic rupture with multiple injuries. A 20-year-old man was transferred to our hospital. He was suffering from traumatic thoracic aortic rupture with multiple injuries (femoral fracture, pelvis fracture and so 4th) due to a traffic accident. Enhanced computed tomography revealed leakage from the aortic isthmus and hematoma in the surrounding area. Emergency operation was performed. The left 4th intercostal thoracotomy was performed and a lacerated foramen was observed across the lesser curvature of the aortic isthmus. The affected site was replaced by a prosthetic graft under percutaneous cardiopulmonary system. He was treated with open fixation of the right femur 11 days after the 1st operation. The postoperative recovery was generally uneventful and he was discharged on the 51st hospital day.