Related Experiment Video
Updated: Apr 24, 2026

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Manikin model with breathing tube for wire-guided percutaneous cricothyrotomy in patients applying an intermaxillary
Kun Hwang1, Han Joon Kim, Yoo Chan Kim
1From the *Department of Plastic Surgery, Inha University School of Medicine, Incheon, South Korea; and †Peninsula Medical School, Exeter, United Kingdom.
Abstract:
Jaw fracture surgery or orthognathic surgery usually involves the application of an intermaxillary fixation (IMF). Obstructions that cannot be relieved by suction require an immediate release of IMF wires, but releasing the IMF may damage the surgical alignment of the facial bones. The mean time taken to release the jaws was an average of 2 minutes 9 seconds by hospital staff involved in caring for these patients. The aims of this study were to introduce a training model for wire-guided percutaneous cricothyrotomy in the patients applying an IMF and to perform the procedure for medical students. Our model consisted of a facial mannequin, a plastic breathing tube, 2 rolls of tapes, and a reservoir bag. The inner parts of the 2 used rolls of tape represent tracheal/cricoid rings (1-inch width for thyroid and half-inch width for cricoid), and the space between them represents the cricothyroid membrane, which is wrapped with Peha-Haft. A surgeon demonstrated the technique on the model, and then, 60 medical students who had never attended airway-training courses applied the Melker cricothyrotomy kit on the model. All 60 students completed the procedure successfully. The mean (SD) time needed to insert a cricothyrotomy catheter of the medical students was 175 (50) seconds (range, 76-297 s). Most of the students (54; 90%) performed it within 4 minutes; more than half (33; 55%), within 3 minutes. With our manikin model and Melker cricothyrotomy kit, 60 medical students completed the procedure successfully. This model can be useful to cricothyrotomy training for medical personnel.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Cardiopulmonary Resuscitation II: ACLS Airway Management