Related Experiment Video
Updated: Apr 24, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Two novel zeolitic imidazolate frameworks (ZIFs) as sorbents for solid-phase extraction (SPE) of polycyclic aromatic
Huiping Hu1, Shengquan Liu, Chunyan Chen
1State Key Laboratory of Chemo/Biosensing & Chemometrics, College of Chemistry & Chemical Engineering, Hunan University, Changsha 410082, China. szyao@hnu.edu.cn shengquanliu7068@163.com.
Abstract:
In this work, two novel zeolitic imidazolate framework (ZIF) materials, ZIF-7 and ZIF-11, were firstly introduced as solid-phase extraction (SPE) sorbents for PAHs efficient extraction and highly sensitive analysis in environmental water samples with high performance liquid chromatography (HPLC) coupled with fluorescence detection. ZIF-7 and ZIF-11 were successfully synthesized and characterized with SEM, FTIR, XRD and water contact angels, exhibiting unique and excellent stability, spatial structure and chemical composition, promising for environmental PAHs efficient enrichment through hydrophobic, π-π and π-complexation interactions. The topology effect on PAHs extraction was compared between ZIF-7 and ZIF-11, considering they have the same composition in metal ion (Zn(2+)) and organic linker, but differing spatial structures: ZIF-7 has a cubic structure, while ZIF-11 is a rhombic dodecahedron. At last, ZIF-11 with markedly better extraction efficiencies was selected for subsequent analysis. Under optimum extraction conditions such as sample volume, extraction time, desorption conditions, volume of organic modifier and salt concentration, a robust and highly efficient method based on ZIF-11 as a novel SPE sorbent has been successfully developed for environmental PAHs analysis. Satisfactory precision and accuracy ranging from 1-2.4 × 10(3) ng L(-1) as well as ultrasensitive detection limits of 0.08-1.6 ng L(-1) have been successfully achieved. Moreover, ZIF-11 extraction also exhibited high recoveries of 82.4-112.7% with relative standard deviations (RSDs) being less than 9% for PAHs in the environmental water samples. Therefore, our novel, convenient and efficient extraction method based on ZIF-11 as a sorbent is promising for applications in future trace-level environmental PAHs analyses.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Extraction: Advanced Methods
Ion Exchange
Ion-Exchange Chromatography