Related Experiment Video
Updated: Apr 24, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Magnetic resonance imaging relaxation times of female reproductive organs
Yasuo Takatsu1, Tsutomu Okada2, Tosiaki Miyati3
1Department of Radiology, Osaka Red Cross Hospital, Osaka, Japan Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University, Kanazawa, Japan pcblue2@yahoo.co.jp.
Background:
Relaxation time of female reproductive organs affects the tissue contrast of magnetic resonance image (MRI), and is used for quantitative analysis.
Purpose:
To evaluate the relaxation times of normal female reproductive organs in the luteal phase of the menstrual cycle.
Material And Methods:
On a 1.5-T MRI, relaxation times were measured in pelvic tissues (endometrium, junctional zone, myometrium, follicle, and stroma) of 32 female healthy volunteers (33.5 ± 6.8 years). The Look-Locker sequence was used to measure T1 relaxation times. Furthermore, a multiple spin-echo method with 32 different echo times was used to measure T2 relaxation times. The images were obtained in the luteal phase of each volunteer's menstrual cycle.
Results:
The measured relaxation times (means ± standard deviations) were as follows: endometrium (T1, 1703 ± 147 ms; T2, 214 ± 35 ms), junctional zone (T1, 1168 ± 63 ms; T2, 72 ± 12 ms), myometrium (T1, 1314 ± 103 ms; T2, 138 ± 20 ms), follicle (T1, 2267 ± 49 ms; T2, 603 ± 68 ms), and stroma (T1, 1481 ± 129 ms; T2, 126 ± 29 ms).
Conclusion:
Reliable MRI measurements of T1 and T2 relaxation times of normal female reproductive organs in the luteal phase of the menstrual cycle are useful as references to recognize the normal value.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...