Related Experiment Video
Updated: Apr 24, 2026

Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017
In vivo predictive dissolution: transport analysis of the CO2 , bicarbonate in vivo buffer system
Brian J Krieg1, Seyed Mohammad Taghavi2, Gordon L Amidon1
1University of Michigan, College of Pharmacy, Ann Arbor, Michigan 48109.
Abstract:
Development of an oral in vivo predictive dissolution medium for acid drugs with a pKa in the physiological range (e.g., Biopharmaceutics Classification System Class IIa) requires transport analysis of the complex in vivo CO2 /bicarbonate buffering system. In this report, we analyze this buffer system using hydrodynamically defined rotating disk dissolution. Transport analysis of drug flux was predicted using the film model approach of Mooney et al based on equilibrium assumptions as well as accounting for the slow hydration reaction, CO2 + H2 O → H2 CO3 . The accuracy of the models was compared with experimentally determined results using the rotating disk dissolution of ibuprofen, indomethacin, and ketoprofen. The equilibrium and slow hydration reaction rate models predict significantly different dissolution rates. The experimental results are more accurately predicted by accounting for the slow hydration reaction under a variety of pH and hydrodynamic conditions. Although the complex bicarbonate buffering system requires further consideration given its dynamic nature in vivo, a simplifying irreversible reaction (IRR) transport analysis accurately predicts in vitro rotating disk dissolution rates of several carboxylic acid drugs. This IRR transport model provides further insight into bicarbonate buffer and can be useful in developing more physiologically relevant buffer systems for dissolution testing.
Related Concept Videos
Bicarbonate-Carbonic Acid Buffer
Theories of Dissolution: Diffusion Layer Model
This process starts with a thin layer, saturated with the drug, forming at the interface between the solid and liquid. The solute then diffuses from this layer into the main solution. The Noyes-Whitney equation suggests that the rate of dissolution relies on the diffusion...
Drug Product Performance: In Vitro–In Vivo Correlation
Theories of Dissolution: The Danckwerts' Model and Interfacial Barrier Model
Titration of Polyprotic Base with a Strong Acid
Factors Affecting Dissolution: Drug pKa, Lipophilicity and GI pH
A drug's pKa and the pH of the gastrointestinal (GI) tract play crucial roles...

