Skin sterility after application of a vapocoolant spray
William F Schleicher1, Bryson G Richards, Franziska Huettner
1*Department of Plastic Surgery, Cleveland Clinic, Cleveland, Ohio; †Plastic and Reconstructive Surgery, Roswell Park Cancer Institute, Buffalo, New York; ‡Northeast Ohio Medical University, Rootstown, Ohio.
Background:
Refrigerant sprays have been widely used to reduce pain in the office setting. However, more recently, their use has been limited by both concern regarding flammability and questions of bacterial contamination.
Objective:
We investigated the microbiological effect of 1,1,1,3,3 pentafluoropropane and 1,1,1,2-tetrafluoroethane when sprayed after povidone-iodine application in 50 volunteers.
Materials And Methods:
In 50 volunteers, 3 cultures were taken (1) at time 0 before antiseptic application, (2) after povidone-iodine topical antiseptic, and (3) after spraying with vapocoolant. Cultures at 3 time intervals were analyzed in a blinded fashion, and Gram stains obtained when cultures were positive.
Results:
Bacterial growth was found in 98% of cultures taken before antiseptic was applied (Group 1), in 28 cultures (56%) after povidone-iodine was applied, and in 24 cultures (48%) after spraying with vapocoolant. There was a statistically significant difference found between Group 1 (no antiseptic) and both Group 2 (after antiseptic but before vapocoolant) and Group 3 (after vapocoolant) (p < .001).
Conclusion:
The topical antiseptic povidone-iodine significantly reduces skin colonization when compared with unprepared skin (p < .001). The vapocoolant 1,1,1,3,3 pentafluoropropane and 1,1,1,2-tetrafluoroethane is sprayed on skin prepared with povidone-iodine; there is no statistically significant increase in bacterial colonization.
More Related Videos
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Hand hygiene
Hand washing...
Chemical Agents for Microbial Control
Physical Methods for Controlling Microbial Growth: Temperature