Related Experiment Video
Updated: Apr 23, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
Photoplethysmographic signal waveform index for detection of increased arterial stiffness
1Department of Biomedical Engineering, Tallinn University of Technology, Ehitajate tee 5, 19086 Tallinn, Estonia.
Abstract:
The aim of this research was to assess the validity of the photoplethysmographic (PPG) waveform index PPGAI for the estimation of increased arterial stiffness. For this purpose, PPG signals were recorded from 24 healthy subjects and from 20 type II diabetes patients. The recorded PPG signals were processed with the analysis algorithm developed and the waveform index PPGAI similar to the augmentation index (AIx) was calculated. As a reference, the aortic AIx was assessed and normalized for a heart rate of 75 bpm (AIx@75) by a SphygmoCor device. A strong correlation (r = 0.85) between the PPGAI and the aortic AIx@75 and a positive correlation of both indices with age were found. Age corrections for the indices PPGAI and AIx@75 as regression models from the signals of healthy subjects were constructed. Both indices revealed a significant difference between the groups of diabetes patients and healthy controls. However, the PPGAI provided the best statistical discrimination for the group of subjects with increased arterial stiffness. The waveform index PPGAI based on the inexpensive PPG technology can be considered as a perspective measure of increased arterial stiffness estimation in clinical screenings.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse
The pulse serves as a clinical...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...