Related Experiment Video
Updated: Apr 23, 2026

Lavage-induced Surfactant Depletion in Pigs As a Model of the Acute Respiratory Distress Syndrome ARDS
Published on: September 7, 2016
Room-temperature vs iced saline indicator injection for transpulmonary thermodilution
Wolfgang Huber1, Thilo Kraski1, Bernhard Haller2
1II. Medizinische Klinik und Poliklinik, Klinikum rechts der Isar, Technische Universität München, Ismaninger Straße 22, D-81675 München, Germany.
Using room-temperature injectate for transpulmonary thermodilution (TPTD) slightly overestimates cardiac index (CI), global end-diastolic volume index (GEDVI), and extravascular lung-water index (EVLWI). Accuracy is acceptable with jugular injection, but not femoral.
Area of Science:
- Critical Care Medicine
- Hemodynamic Monitoring
- Physiology
Background:
- Transpulmonary thermodilution (TPTD) is crucial for hemodynamic monitoring in intensive care.
- Ice-cold injectate is traditionally used for TPTD to ensure accuracy.
- Room-temperature injectate offers potential convenience but its impact on accuracy is debated.
Purpose of the Study:
- To compare the accuracy of TPTD-derived measurements using room-temperature injectate versus traditional ice-cold injectate.
- To evaluate the influence of injectate temperature on cardiac index (CI), global end-diastolic volume index (GEDVI), and extravascular lung-water index (EVLWI).
Main Methods:
- An observational study involving 45 adult ICU patients with PiCCO monitoring.
- 401 sets of TPTD measurements were recorded, using both 21°C (room-temperature) and 4°C (ice-cold) saline injectates.
- Mean values from two room-temperature TPTDs were compared against mean values from two ice-cold TPTDs.
Main Results:
- Room-temperature TPTD (TPTDRoom) showed statistically significant overestimations for CI, GEDVI, and EVLWI compared to ice-cold TPTD.
- Mean bias and percentage errors were within acceptable limits for CI, but higher for GEDVI and EVLWI.
- Percentage errors were notably higher with femoral indicator injection compared to jugular injection for all measured parameters.
Conclusions:
- Room-temperature injectate in TPTD leads to a slight but significant overestimation of key hemodynamic parameters (CI, GEDVI, EVLWI).
- The accuracy of room-temperature TPTD for GEDVI and EVLWI is acceptable only when using jugular indicator injection.
- Clinical decisions based on TPTD using room-temperature injectate require careful consideration of the injection site and potential overestimation.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...