Concordance between digital pathology and light microscopy in general surgical pathology: a pilot study of 100 cases
Joseph P Houghton1, Aaron J Ervine2, Sarah L Kenny2
1Centre for Medical Education, Queen's University Belfast, Belfast, N. Ireland.
Aim:
(1) A pilot study to determine the accuracy of interpretation of whole slide digital images in a broad range of general histopathology cases of graded complexity. (2) To survey the participating histopathologists with regard to acceptability of digital pathology.
Materials And Methods:
Glass slides of 100 biopsies and minor resections were digitally scanned in their entirety, producing digital slides. These cases had been diagnosed by light microscopy at least 1 year previously and were subsequently reassessed by the original reporting pathologist (who was blinded to their original diagnosis) using digital pathology. The digital pathology-based diagnosis was compared with the original glass slide diagnosis and classified as concordant, slightly discordant (without clinical consequence) or discordant. The participants were surveyed at the end of the study.
Results:
There was concordance between the original light microscopy diagnosis and digital pathology-based diagnosis in 95 of the 100 cases while the remaining 5 cases showed only slight discordance (with no clinical consequence). None of the cases were categorised as discordant. Participants had mixed experiences using digital pathology technology.
Conclusions:
In the broad range of cases we examined, digital pathology is a safe and viable method of making a primary histopathological diagnosis.
Related Concept Videos
Two-Dimensional Microscopy in Microbiology
Confocal Fluorescence Microscopy
Three-Dimensional Microscopy in Microbiology
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Overview of Microscopy Techniques