A wearable respiratory monitoring device--the between-days variability of calibration
C Heyde1, H Mahler1, K Roecker2
1Albert Ludwigs Universtity Freiburg, Department of Sport and Sport Science, Freiburg, Germany.
Abstract:
The between-days variability in ascertained gain factors for calibration of a wearable respiratory inductance plethysmograph (RIP) and validity thereof for the repeated use during exercise were examined. Consecutive 5-min periods of standing still, slow running at 8 km·h(-1), fast running at 14 km·h(-1) (male) or 12 km·h(-1) (female) and recovery were repeated by 10 healthy subjects on 5 days. Breath-by-breath data were recorded simultaneously by flow meter and RIP. Gain factors were determined individually for each trial (CALIND) via least square regression. Reliability and variability in gain factors were quantified respectively by intraclass correlation coefficients (ICC) and limits of agreement. Within a predefined error range of ±20% the amount of RIP-derived tidal volumes after CALIND was compared to corresponding amounts when gain factors of the first trial were applied on the following 4 trials (CALFIRST). ICC ranged within 0.96 and 0.98. The variability in gain factors (up to ± 24.06%) was reduced compensatively by their sum. Amounts of breaths within the predefined error range did not differ between CALIND and (CALFIRST) (P>0.32). The between-days variability of gain factors for a wearable RIP-device does not show impaired reliability in further derived tidal volumes.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Errors occurring during blood pressure monitoring
Several factors...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: