Related Experiment Video
Updated: Apr 23, 2026

Physical Activity Measurement in Children Accepting Table Tennis Training
Published on: July 27, 2022
Measuring reliability and validity of the ActiGraph GT3X accelerometer for children with cerebral palsy: a
Margaret E O'Neil1, Maria A Fragala-Pinkham2, Jeffrey L Forman3
1Department of Physical Therapy and Rehabilitation Sciences, College of Nursing and Health Professions, Drexel University, Philadelphia, PA, USA.
Purpose:
The purposes of this study were to: 1) establish inter-instrument reliability between left and right hip accelerometer placement; 2) examine procedural reliability of a walking protocol used to measure physical activity (PA); and 3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry.
Methods:
Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b
Results:
Inter-instrument reliability of ActiGraph GT3X accelerometers placed on left and right hips was excellent (ICC=0.96-0.99, CI
Conclusion:
This preliminary research suggests that ActiGraph GT3X accelerometers are reliable and valid devices to monitor PA during walking in children with CP and may be appropriate in rehabilitation research and clinical practice. ActiGraph GTX3 step counts were not valid for this sample and further research is warranted.