Raman spectroscopic quantitative study of NaCl-CaCl2-H2O system at high temperatures and pressures
Abstract:
Raman spectra features of the ternary system NaCl-CaCl2-H2O under high temperatures and high pressures were systematically studied in the present work by using hydrothermal diamond anvil cell (HDAC) and Raman shifts of quartz to determine pressures, and it has been obtained for the quantitative relationship between Raman shifts of the O-H stretching band of water, mass fractions of solutes and pressures was obtained. The mass fractions of salts, where salinity of NaCl equal to that of CaCl2, are 4.0 mass %, 8.0 mass %, and 12.0 mass %, respectively. Experimental results indicate that the standardized Raman frequency shift differences of the O-H stretching vibration (deltav(O0H)) rise with the increasing temperatures when the mass fractions of salts and pressures of the NaCl-CaCl2-H2O system remain constant. deltav(O-H) increases with the increase in mass fractions of salts in the system when the temperatures and pressures are constant. Linear relationship between deltav(O-H) and pressure with similar slopes can be found for the NaCl-CaCl2-H2O system with different salinities. The quantitative relationship between deltav(O-H), temperature (T), pressure (P), and mass fraction of solute (M) is P = -31.892 deltav(O-H) + 10.131T + 222.816M - 3 183.567, where the valid PTM range of the equation is 200 MPa < or = P < or = 1 700 MPa, 273 K < or = T < or = 539 K and M < or = 12 mass %. The equation can be used as a geobarometer in the studies of fluid inclusions of NaCl-CaCl2-H2O system with equal salinities. The method, as a direct geological detecting technique, has a potential application value.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Constant Volume Calorimetry
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution


