The repeated sit-to-stand maneuver is a superior method for cardiac baroreflex assessment: a comparison with the modified Oxford method and Valsalva maneuver
Related Experiment Video
Updated: Apr 23, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
H M Horsman1, Y C Tzeng1, D C Galletly1
1Cardiovascular Systems Laboratory; Centre for Translational Physiology, University of Otago, Wellington, New Zealand;
Abstract:
Baroreflex assessment has diagnostic and prognostic utility in the clinical and research environments, and there is a need for a reliable, simple, noninvasive method of assessment. The repeated sit-to-stand method induces oscillatory changes in blood pressure (BP) at a desired frequency and is suitable for assessing dynamic baroreflex sensitivity (BRS). However, little is known about the reliability of this method and its ability to discern fundamental properties of the baroreflex. In this study we sought to: 1) evaluate the reliability of the sit-to-stand method for assessing BRS and compare its performance against two established methods (Oxford method and Valsalva maneuver), and 2) examine whether the frequency of the sit-to-stand method influences hysteresis. Sixteen healthy participants underwent three trials of each method. For the sit-to-stand method, which was performed at 0.1 and 0.05 Hz, BRS was quantified as an integrated response (BRSINT) and in response to falling and rising BP (BRSDOWN and BRSUP, respectively). Test retest reliability was assessed using the intraclass correlation coefficient (ICC). Irrespective of frequency, the ICC for BRSINT during the sit-to-stand method was ≥0.88. The ICC for a rising BP evoked by phenylephrine (PEGAIN) in the Oxford method was 0.78 and ≤0.5 for the remaining measures. During the sit-to-stand method, hysteresis was apparent in all participants at 0.1 Hz but was absent at 0.05 Hz. These findings indicate the sit-to-stand method is a statistically reliable BRS assessment tool and suitable for the examination of baroreflex hysteresis. Using this approach we showed that baroreflex hysteresis is a frequency-dependent phenomenon.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure