Related Experiment Video
Updated: Apr 23, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Fast determination of 40 drugs in water using large volume direct injection liquid chromatography-tandem mass
Clara Boix1, María Ibáñez1, Juan V Sancho1
1Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, s/n-12071 Castellón, Spain.
Abstract:
This work describes a rapid analytical method based on direct sample injection of water samples for the simultaneous identification/quantification of 40 emerging compounds, including pharmaceuticals and drugs of abuse. The water samples were analyzed by ultra-high-performance liquid chromatography coupled to hybrid triple quadrupole mass spectrometer (UHPLC-MS/MS QqQ). Taking profit of the increasing sensitivity of nowadays tandem mass spectrometers, direct sample injection of large volumes has been an attractive alternative to pre-concentration steps. In this work, the developed methodology has been validated at three concentration levels (10, 100 and 1000 ng/L) in 10 different water samples of different types (5 effluent wastewater and 5 surface water samples). The majority of compounds could be satisfactory validated at these concentrations, showing good recoveries and precision. With only few exceptions, the limits of quantification (LOQs), estimated from the sample chromatogram at lowest spiked level tested, were below 3 ng/L. The method was applied to the analysis of 10 effluent wastewater and 10 surface water samples. Venlafaxine was the compound most frequently detected (80%) in surface water, followed by acetaminophen (70%). Regarding effluent wastewater, valsartan and 4-acetyl aminoantipyrine were detected in 9 out of 10 samples analyzed. These two compounds together with 4-formyl aminoantipyrine and naproxen showed the highest concentrations (>2000 ng/L). In these cases, a dilution step was required for a correct quantification. As an additional evaluation of the method performance, the same water samples were analyzed in another laboratory by a second analytical methodology, based on on-line solid-phase-extraction coupled to LC-MS/MS (QqQ).
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018