Related Experiment Video
Updated: Apr 22, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
MRI Meets MPI: a bimodal MPI-MRI tomograph
Abstract:
While magnetic particle imaging (MPI) constitutes a novel biomedical imaging technique for tracking superparamagnetic nanoparticles in vivo, unlike magnetic resonance imaging (MRI), it cannot provide anatomical background information. Until now these two modalities have been performed in separate scanners and image co-registration has been hampered by the need to reposition the sample in both systems as similarly as possible. This paper presents a bimodal MPI-MRI-tomograph that combines both modalities in a single system.MPI and MRI images can thus be acquired without moving the sample or replacing any parts in the setup. The images acquired with the presented setup show excellent agreement between the localization of the nanoparticles in MPI and the MRI background data. A combination of two highly complementary imaging modalities has been achieved.
Insights
This study introduces a novel bimodal magnetic particle imaging (MPI) and magnetic resonance imaging (MRI) tomograph. The combined system enables simultaneous imaging without sample repositioning, improving nanoparticle localization accuracy.
Area of Science:
- Biomedical Imaging
- Medical Physics
- Nanotechnology
Background:
- Magnetic particle imaging (MPI) tracks superparamagnetic nanoparticles in vivo.
- MPI lacks anatomical background information, unlike magnetic resonance imaging (MRI).
- Previous bimodal imaging required separate scanners and complex sample repositioning.
Purpose of the Study:
- To develop a single, bimodal MPI-MRI-tomograph.
- To enable simultaneous image acquisition without sample movement.
- To improve the co-registration and accuracy of MPI and MRI data.
Main Methods:
- Integration of MPI and MRI hardware into a single tomograph.
- Acquisition of both MPI and MRI data from the same sample position.
- Validation of image co-registration between the two modalities.
Main Results:
- Demonstration of a functional bimodal MPI-MRI-tomograph.
- Simultaneous acquisition of MPI and MRI images without sample repositioning.
- Excellent agreement between nanoparticle localization (MPI) and anatomical background (MRI).
Conclusions:
- A combined MPI-MRI system overcomes limitations of individual modalities.
- The bimodal tomograph facilitates accurate nanoparticle tracking with anatomical context.
- This integrated approach enhances the utility of MPI and MRI in biomedical applications.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging

