Related Experiment Video
Updated: Apr 22, 2026

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
A robust approach to correct for pronounced errors in temperature measurements by controlling radiation damping
Stephanie M Wolahan1, Zhao Li1, Chao-Hsiung Hsu2
1Department of Chemistry and Biochemistry, University of California at Los Angeles, Los Angeles, CA 90095, United States.
Abstract:
Accurate temperature measurement is a requisite for obtaining reliable thermodynamic and kinetic information in all NMR experiments. A widely used method to calibrate sample temperature depends on a secondary standard with temperature-dependent chemical shifts to report the true sample temperature, such as the hydroxyl proton in neat methanol or neat ethylene glycol. The temperature-dependent chemical shift of the hydroxyl protons arises from the sensitivity of the hydrogen-bond network to small changes in temperature. The frequency separation between the alkyl and the hydroxyl protons are then converted to sample temperature. Temperature measurements by this method, however, have been reported to be inconsistent and incorrect in modern NMR, particularly for spectrometers equipped with cryogenically-cooled probes. Such errors make it difficult or even impossible to study chemical exchange and molecular dynamics or to compare data acquired on different instruments, as is frequently done in biomolecular NMR. In this work, we identify the physical origins for such errors to be unequal amount of dynamical frequency shifts on the alkyl and the hydroxyl protons induced by strong radiation damping (RD) feedback fields. Common methods used to circumvent RD may not suppress such errors. A simple, easy-to-implement solution was demonstrated that neutralizes the RD effect on the frequency separation by a "selective crushing recovery" pulse sequence to equalize the transverse magnetization of both spin species. Experiments using cryoprobes at 500 MHz and 800 MHz demonstrated that this approach can effectively reduce the errors in temperature measurements from about ±4.0 K to within ±0.4 K in general.
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Absorption of Radiation