Background:
Proteinuria has been associated with transplant loss and mortality in kidney transplant recipients. Both spot samples (albumin-creatinine ratio [ACR] and protein-creatinine ratio [PCR]) and 24-hour collections (albumin excretion rate [AER] and protein excretion rate [PER]) have been used to quantify protein excretion, but which measurement is a better predictor of outcomes in kidney transplantation remains uncertain.
Study Design:
Observational cohort study.
Setting & Participants:
Tertiary care center, 207 kidney transplant recipients who were enrolled in a prospective study to measure glomerular filtration rate. Consecutive patients who met inclusion criteria were approached.
Predictors:
ACR and PCR in spot urine samples, AER and PER in 24-hour urine collections.
Outcomes:
Primary outcome included transplant loss, doubling of serum creatinine level, or death.
Measurements:
Urine and serum creatinine were measured using a modified Jaffé reaction that had not been standardized by isotope-dilution mass spectrometry. Urine albumin was measured by immunoturbidimetry. Urine protein was measured by pyrogallol red molybdate complex formation using a timed end point method.
Results:
Mean follow-up was 6.4 years and 22% developed the primary end point. Multivariable-adjusted areas under the receiver operating characteristic curves were similar for the different protein measurements: ACR (0.85; 95% CI, 0.79-0.89), PCR (0.84; 95% CI, 0.79-0.89), PER (0.86; 95% CI, 0.80-0.90), and AER (0.83; 95% CI, 0.78-0.88). C Index values also were similar for the different proteinuria measurements: 0.87 (95% CI, 0.79-0.95), 0.86 (95% CI, 0.79-0.94), 0.88 (95% CI, 0.82-0.94), and 0.86 (95% CI, 0.77-0.95) for log(ACR), log(PCR), log(PER), and log(AER), respectively.
Limitations:
Single-center study. Measurement of proteinuria was at variable times posttransplantation.
Conclusions:
Spot and 24-hour measurements of albumin and protein excretion are similar predictors of doubling of serum creatinine level, transplant loss, and death. Thus, spot urine samples are a suitable alternative to 24-hour urine collection for measuring protein excretion in this population.
Related Concept Videos
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Nephrotic Syndrome II : Assessment and Medical Management
Kidney Transplant II: Surgical Procedure
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Kidney Transplant III: Nursing Management