Oxidative status in different settings and with different methodological approaches compared by Receiver Operating
Giuliana Cighetti1, Fabrizia Bamonti2, Caroline S Aman1
1Dipartimento di Scienze Biomediche e Cliniche "L. Sacco", Università degli Studi di Milano, Milano, Italy.
Clinical Biochemistry
|October 12, 2014
Summary
Total malondialdehyde (T-MDA) is the best marker for detecting oxidative stress, outperforming other assays. This study evaluated various methods to identify deregulated redox status in different health conditions.
Area of Science:
- Biochemistry
- Clinical Chemistry
- Biomarkers
Background:
- Redox status is crucial in various physiological and pathological conditions.
- Assessing oxidative stress and antioxidant capacity is vital for understanding disease mechanisms.
Purpose of the Study:
- To evaluate the performance of different analytical methods in detecting deregulated redox status.
- To compare the efficacy of Total Malondialdehyde (T-MDA), Free Malondialdehyde (F-MDA), Reactive Oxygen Metabolites (d-ROMs), and Total Antioxidant Capacity (TAC) assays.
Main Methods:
- Retrospective analysis of data from smokers, chronic renal failure patients, kidney transplant recipients, and healthy controls.
- Quantification of oxidative stress and antioxidant status using spectrophotometric and isotope-dilution-gas chromatography-mass spectrometry methods.
- Receiver Operating Characteristic (ROC) analyses and area under the ROC curve (AUC) to determine sensitivity, specificity, and cut-off points.
Main Results:
- T-MDA demonstrated 100% sensitivity and specificity with an AUC of 1.00, indicating it as a superior marker for oxidative stress.
- d-ROMs (AUC 0.87) and F-MDA (AUC 0.82) showed good accuracy in detecting altered redox status.
- TAC assays exhibited lower performance (AUC 0.66) in identifying impaired antioxidant defense.
Conclusions:
- T-MDA is identified as the most reliable marker for detecting oxidative stress.
- d-ROMs can effectively identify modified oxidative status, especially in cases of significant damage.
- While d-ROMs and TAC may be useful for routine screening, validation against gold standard methods is necessary for accurate clinical interpretation.
Keywords:
Antioxidant statusIsotope-dilution-gas chromatography–mass spectrometryMalondialdehydeMethod comparisonOxidative stressROC curve analysisMore Related Videos
Related Concept Videos
Receiver Operating Characteristic Plot
561
A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
561
Special considerations while measuring oxygen saturation
1.0K
Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
1.0K
Pulse Oximetry
1.5K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.5K